Changmei Medtech Dilatation Balloon Catheter with CE Certificate
Intended use:
This devices is mainly used for dilating the digestive tract stricture and adjuvant therapy.
Features:
· Elastic soft tip design, which can smoothly enter into the target position with less tissue damage;
· The balloon is of extra transparent, which is convenient for observing during the dilation process;
· The balloon is using imported material with high pressure resistance, less deformation and safer
dilation;
· Thermostatic shaping after multi-wing pleating contributes to excellent resilience and flexible retreat
from working channel;
· Optimal design of the tube is smooth and of good elasticity, strong twisting resistance and easier
passability;
· The radiopaque markers on the balloon can provide precise positioning under X-ray.
Specifications:
Dilation balloon for Esophagus/Pylorus/Colonic:
Model | Channnel O.D. (mm) |
Working Length (mm) |
Balloon Size (mm) |
Guide Wire (in) |
BD-28N-0640 | ≥2.8 | 1800 | 0640 | 0.035" |
BD-28N-0840 | ≥2.8 | 1800 | 0840 | 0.035" |
BD-28N-1040 | ≥2.8 | 1800 | 1040 | 0.035" |
BD-28N-1260 | ≥2.8 | 1800 | 1260 | 0.035" |
BD-28N-1460 | ≥2.8 | 1800 | 1460 | 0.035" |
BD-28N-1680 | ≥2.8 | 1800 | 1680 | 0.035" |
BD-28N-1880 | ≥2.8 | 1800 | 1880 | 0.035" |
BD-28U-1880 | ≥2.8 | 2300 | 1880 | 0.035" |
BD-28N-2060 | ≥2.8 | 1800 | 2060 | N/A |
BD-28N-2080 | ≥2.8 | 1800 | 2080 | N/A |
BD-32U-2060 | ≥2.8 | 2300 | 2060 | 0.035" |
BD-32U-2080 | ≥3.2 | 2300 | 2080 | 0.035" |
Dilation balloon for cardia:
Model | Channnel O.D. (mm) |
Working Length (mm) |
Balloon Size (mm) |
Guide Wire (in) |
BD-00A-2580 | N/A | 900 | 2580 | 0.035" |
BD-00A-3080 | N/A | 900 | 3080 | 0.035" |
BD-00A-3580 | N/A | 900 | 3580 | 0.035" |
Dilation balloon for biliary tract:
Model | Channnel I.D. (mm) |
Working Length (mm) |
Balloon Size (mm) |
Guide Wire (in) |
BD-28Q-0640 | ≥2.8 | 2000 | 0640 | 0.035" |
BD-28Q-0840 | ≥2.8 | 2000 | 0840 | 0.035" |
BD-28Q-1040 | ≥2.8 | 2000 | 1040 | 0.035" |
BD-28Q-12-60 | ≥2.8 | 2000 | 1260 | 0.035" |
BD-28Q-14-60 | ≥2.8 | 2000 | 1460 | 0.035" |
Dilation balloon for choledochofiberscope:
Model | Channnel I.D. (mm) |
Working Length (mm) |
Balloon Size (mm) |
Guide Wire (in) |
BD-20A-0640 | ≥2.0 | 900 | 0640 | 0.032" |
BD-20A-0840 | ≥2.0 | 900 | 0840 | 0.032" |
BD-20N-0640 | ≥2.0 | 1800 | 0640 | 0.032" |
BD-20N-0840 | ≥2.0 | 1800 | 0840 | 0.032" |
Other Dilation balloon:
Model | Channnel I.D. (mm) |
Working Length (mm) |
Balloon Size (mm) |
Guide Wire (in) |
BD-28D-0640 | ≥2.8 | 1100 | 0640 | 0.032" |
BD-28D-0840 | ≥2.8 | 1100 | 0840 | 0.032" |
BD-28D-1040 | ≥2.8 | 1100 | 1040 | 0.032" |
BD-28D-1260 | ≥2.8 | 1100 | 1260 | 0.032" |
BD-28D-1460 | ≥2.8 | 1100 | 1460 | 0.032" |
BD-28D-1680 | ≥2.8 | 1100 | 1680 | 0.032" |
BD-28D-1880 | ≥2.8 | 1100 | 1880 | 0.032" |